➤ Standard Chamber with one cavity designed by JIUPO, multiple applications for tissue culture, small plant, tall plant growth.
➤ BPC2000H is specifically designed for plant growth light quality studies and other experiments requiring specific wavelengths or full-spectrum wavelengths of light, capable of achieving extreme conditions of temperature, lighting levels, and humidity. The product is well suited for research applications requiring a high level of control in a relatively small footprint. In addition to customizable environmental control parameters, options are also available for growth height, gas levels. The BPC2000H offers a maximum growth height of 66.9” (170cm) or a 51.1 ft² (4.75m²) growth area.
➤ Many other applications exist for this product.
➤ Counterbalanced Lighting system ➤ Standard lighting provides a wide spectrum at high intensity ➤ Certifications / markings: ISO9001, CE |
Lighting System • This facilitates precise light intensity levels to be maintained throughout the life of experiment. Standard light intensity is 750 μE - m²s (10cm from the lights) which is measured by a quantum light meter and transmitted to the controller for user readout. • Standard color choices include cool white, full-spectrum LEDs. • Non-standard color choices include blue, red, far red, red-blue-far red combination, red-green-blue combination, red-blue-far red-white combination LEDs. • Non-standard light intensity choices include 300/500/1000/1900 μE - m²s (10cm from the lights). • Each color is independently dimmable between 0% to 100%. • Programming and control of the lighting is done via JIUPO real time controller. |
Air Flow Air flow for the BPC2000H is distributed uniformly outward from both sides of the walls and back through the air pump on back side of the cabinet, which using JIUPO innovative horizontal-air-refresh distribution plenum. Airflow is sufficient to ensure uniformity as well as proper gas exchange at the leaf surface. Fresh air intake can be adjustable which also helps to ensure adequate ambient gas exchange. |
Refrigeration • Self-contained air-cooled condensing unit with hot gas bypass system for continuous compressor operation, extended life and close temperature control. An electronic modulating valve provides tight temperature control while ensuring quiet operation. Pressure transducers are included for monitoring the status of the refrigeration system. • Solenoid valves have extended stem for quiet and long life operation. • Rear chamber wall mounted evaporator coil incorporates an air circulation fan. |
Safety Limit Controls • Adjustable high and low temperature / humidity / pressure controls, audible alarms, and visual indicators display on the screen. • Controls shut down all power to the chamber, activating alarms (when the temperature / humidity / pressure returns to the normal range the system will automatically reset). • Backup “high / low” alarms provide a further level of protection while visual and audible notification is provided when any alarm is activated. Contacts for connection to a remote management system are also included. |
Standard | Options | |
Temp. Range (Lights ON) | +3℃ to +45℃ | -10℃ to +45℃ |
Temp. Range (Lights OFF) | ||
Temp. Precision | 0.1℃ | |
Temp. Uniformity (In Time) | ≤0.5℃ | |
Temp. Uniformity (In Space) | ±2℃ (Lights ON)[1] | |
Humidity Range (Lights ON) | 50%RH to 90%RH | 30%RH to 90%RH |
Humidity Range (Lights OFF) | ||
Humidity Precision | 1%RH | |
Humidity Uniformity (In Time) | ≤3%RH | |
Humidity Uniformity (In Space) | ±5%RH (Lights ON)[1] | |
Growth Space | 2138L | |
Layers | 5 | |
Maximum Growth Height | 170cm | |
Exterior Dimensions | 2400×1000×2010mm (W×D×H) | |
Lights Intensity | 300 μmol/m²·S (@10 cm under light) | 500/1000/1600 μmol/m²·S (@10 cm under light) |
Option lights Color | - | Three Colors/ Four Colors |
CO2 | - | with 2000/5000PPM Sensor |
Camera | - | with Camera Inside |
Smart Phone APP Remote Control System | - | Equipped with smart phone app remote control system |
Power Supply | 220VAC / 50HZ |
[1] Different intensity lighting lamp can cause heat dissipation, which affects the performance of temperature and humidity uniformity.